Can FFPE Tissue Be Used for Proteomics?
Yes. One 4 µm FFPE section on a single glass slide gave a median of 7,097 proteins per lung cancer biopsy in the 68-patient cohort reported by Berkovska and colleagues (2026). Archival blocks are a workable proteomics input, not a compromise. The constraint is quantity: yields ran from 55 ng to 1 µg of peptide per slide, so the LC-MS method must handle nanogram loads.
Key Takeaways
FFPE proteomics from one 4 µm section identifies 5,000 to 8,000 proteins per sample on current DIA instruments.
Peptide yield from a single slide is 55 ng to 1 µg, so methods must handle nanogram injections.
Multiple sections still give deeper coverage; a single slide is enough for histology markers and immune signatures.
Single-Slide FFPE Proteomics on Astral and timsTOF
Sixty-eight unresectable lung cancer biopsies from the Oslo DART trial (core needle, forceps, cryobiopsy) supplied one 4 µm section each. Fifteen Karolinska reference cases contributed five 5 µm sections apiece, macrodissected by a pathologist. Slides were washed in 0.01% DDM, scraped, extracted with xylene-free heat and ultrasonication, then digested on-bead with Lys-C and trypsin. After MS-based yield estimation on 10% of each sample, the rest ran as 50 ng on an Orbitrap Astral or 50 to 200 ng by dia-PASEF on a timsTOF HT.
Key Findings
Median depth per slide: 7,097 proteins on the Orbitrap Astral and 6,629 on the timsTOF HT.
Over 90% of slides exceeded 5,000 proteins; six of 68 samples were low-yield outliers.
Histology markers separated 26 adenocarcinomas from 34 squamous carcinomas, most cleanly in core needle biopsies.
OncoKB actionable targets: 63 to 72% detected per slide; PD-L1 seen in 33 to 54% of IHC-positive cases.

Figure 1. Two-cohort workflow (A), peptide yield estimation (B), per-sample amounts (C), protein identifications by instrument (D), Astral versus timsTOF overlap (E), and data completeness (F). Adapted from Berkovska et al. (2026), npj Precision Oncology.
What Limits Depth on a Single Slide
Input, not chemistry. Multi-section medians reached 7,557 (Astral) and 6,980 (timsTOF) proteins, above single-slide values, while the same samples on an older Exploris 480 with a 120 min gradient gave roughly 4,000. Instrument generation mattered more than gradient length. Skin keratin tracked negatively with protein counts, hemoglobin added variance, and forceps biopsies that pinch through bronchial epithelium diluted tumor signal. The extraction follows the streamlined FFPE workflow of Coscia and colleagues (2020).
What the Slides Supported Clinically
Routine pathology marker scores split adenocarcinoma from squamous cell carcinoma on both instruments, though less cleanly than expected. The 18-marker tumor inflammation signature agreed closely between Astral and timsTOF, and 58% of 782 published immune markers were detected. PD-L1 is the weak point: 80% of IHC-positive cases were caught in multi-section Astral data but only 33 to 54% elsewhere. Missing tumor-cellularity data leave the immune signatures partly interpretable at best. For treatment-response biomarkers, see Multi-Omics: Plasma Shifts Track T-DXd in Breast Cancer.
In Practice: Scaling From Slides to Blocks
A single 4 µm section is the floor for input, and most archival studies don't need to live there. When blocks or scrolls are available, we ask for 30 to 50 mg of tissue per sample, with 10 mg as the minimum, for the tissue work that comes through Proteomics Services at Dalton; that extra input is what separates a 5,000-protein slide from a 7,500-protein dataset.
Frequently Asked Questions
Can FFPE tissue be used for proteomics?
Yes. Modern DIA instruments recover deep proteomes from formalin-fixed sections; one 4 µm lung cancer section yielded a median of 7,097 proteins.
How many proteins can proteomics identify from a single FFPE slide?
Between 5,000 and 8,000 per sample on an Orbitrap Astral or timsTOF HT; 10,107 proteins were identified across 68 single-slide lung biopsies.
How much FFPE tissue should I send for a proteomics project?
Send 30 to 50 mg of tissue per sample, 10 mg at minimum, and plan at least 20 samples per project.
Conclusion
Single-slide FFPE proteomics is believable as a routine input on current-generation instruments. What isn't proven is whether 33 to 54% PD-L1 detection can stand in for immunohistochemistry, or how tumor content shaped the immune signatures. Keep multi-section pooling as the default and reserve single slides for where nothing else exists.
Related Reading
See how we run these analyses in one lab: One-Shot Multi-Omics CRO for Drug Development.
Citation
Berkovska, O., Schliemann, I., Mermelekas, G., Özkan, N. E., Nikpour, M., Haakensen, V. D., Helland, Å., Lehtiö, J., & Orre, L. M. (2026). Mass spectrometry-based proteomics delivers in-depth proteome profiling of FFPE lung cancer biopsies from single glass slides. npj Precision Oncology, 10, 196. https://doi.org/10.1038/s41698-026-01517-8
Note
This blog post summarizes findings from the above-cited research. Figures are adapted from the original publication. For full details, please refer to the source article.
By Seungjun Yeo, CEO at Dalton Bioanalytics. Specializing in multi-omics mass spectrometry for drug discovery and biomarker research.